OBS-P1 Optical Shutter
$42.98
$56.3
DescriptionProduct DescriptionBlade-type optoelectronic shutter with millisecondlevel operation.SM05 (0.535″-40) threaded aperture, compatible with SM05 lens tubes.Closing response time: 10 ms typical (20%–80% exposure) with OBS-C1 controller.Default state: closed.Compatible with OBS-C1 controller (sold separately).The bladetype optoelectronic shutter provides millisecondlevel operation, ideal for blocking/unblocking laser beams. ItemSpecificationModelOBS-P1Dimensions84.8 × 57.1 × 31.1 mmShutter ApertureSM05 (0.535″-40) female threadConnector6pin XS2 (M8) maleMounting ThreadM4 holesWeight218.4 gTiming Performance ItemTypical Time (ms)TI8.0TO3.0TD/R13.0TC4.1MSOP*27.0MOP10.0DefinitionsTI (Transfer Initialization): Time from voltage application to initial shutter movement.TO (Transfer Open): Time from 20% to 80% exposure, measured over 1/2inch travel.TD/R (Transfer Dwell/Release): Time from voltage/pulse removal to shutter closing start.TC (Transfer Close): Time from 80% to 20% exposure during closing.MSOP* (Minimum Shutter Opening Time): Minimum open time using MOP from OBS-C1.MOP (Minimum Open Pulse): Minimum pulse width of OBS-C1 controller.OBS-C1 Optoelectronic Shutter ControllerThe OBS-C1 drives and controls one channel of optoelectronic shutter or other solenoid devices. It works with Oeabt OBS-P1 and compatible current/pulsedriven actuators. ItemSpecificationModelOBS-C1Dimensions76.0 × 74.2 × 47.0 mm (knob excluded)Output VoltageDC 12 VShutter Connector6pin XS2 (M8) maleCommunicationUSBExternal TriggerSMAAccessories12V power supply, 1 m XS2 cable, KCH-A1 baseWeight177.5 g Technical Notes The OBS-P1 features an SM05 threaded aperture with a swinging blade, enabling millisecondlevel operation. It remains closed by default and opens only when a control pulse is received. Speed and frequency are adjustable via the OBS-C1 controller (sold separately).The OBS-C1 controller drives and controls one channel of optoelectronic shutter or solenoid devices. A toggle switch powers the controller on/off. It connects to the OBS-P1 and other compatible actuators.Controller Main Menu (full manual available upon request): Mode: Manual, Auto, External TriggerShutter Settings: Set on/off durations in 100 ms steps (multiples of minimum duration)Display: Adjust brightness and sleep timeoutThe shutter stays open if the control voltage is maintained above the threshold; it closes when voltage drops below the threshold.Multiple units can be linked via trigger I/O for synchronized or asynchronous multi-channel operation.AssemblyApplication ExamplesEngineering DrawingsOBS-P1 Engineering DrawingOBS-C1 Engineering Drawing
Optical Rails