TMPRESS.ES ≡ Scottish Jewels Aerials America Power Cords Pirs
  • Olympus

  • High Temperature Ultrasonic Thickness Gauge Probe GT‑12‑2 Premium UT Transducer For Industrial Precision

High Temperature Ultrasonic Thickness Gauge Probe GT‑12‑2 Premium UT Transducer For Industrial Precision

$50.09 $91.16
The High Temperature Ultrasonic Thickness Gauge Probe GT‑12‑2 is a professional‑grade, 5 MHz ultrasonic transducer designed for accurate thickness measurement of metal and high‑temperature materials in industrial environments. Engineered for durability and superior performance, this UT probe transducer excels in challenging conditions where heat resistance, measurement reliability, and repeatability are critical.With a temperature tolerance of −20 to 350 °C, this high‑temperature thickness gauge probe delivers consistent results in applications that conventional probes cannot handle. When paired with compatible ultrasonic thickness gauges, such as models in the GT series, the GT‑12‑2 becomes one of the most dependable tools for non‑destructive evaluation (NDE), quality control, and surface integrity assessments.Why Choose the GT‑12‑2 High Temperature Ultrasonic Thickness Probe?Unmatched Heat ResistanceIndustrial assets and systems often operate under extreme temperature conditions. Whether you’re inspecting boiler tubes, pressure vessels, pipelines, storage tanks, heat exchangers, or automotive and aerospace components, you need a transducer that can withstand harsh thermal environments.The GT‑12‑2 UT transducer has a temperature range from −20 °C up to 350 °C (662 °F), making it ideal for:High‑temperature process inspectionElevated surface measurementInspection of materials immediately after heat treatmentIn‑place measurements during plant maintenanceThis robust heat resistance ensures stable, repeatable thickness measurements even when the test surface is too hot for standard probes.Accurate Ultrasonic Thickness Testing with 5 MHz FrequencyThe 5 MHz operating frequency of the GT‑12‑2 ultrasonic thickness gauge probe balances penetration depth and resolution, providing precise measurement results across a broad range of industrial materials.High frequency enables the GT‑12‑2 to deliver:Accurate readings on thin to moderately thick materialsExcellent signal quality with reduced noiseImproved definition of echo responsesAt 5 MHz, this transducer is versatile enough for use in metals, plastics, composites, and other engineering materials where ultrasonic thickness measurement is crucial.Technical Specifications at a GlanceBelow is a comprehensive specification table designed to help you quickly understand the core capabilities of the GT‑12‑2 probe:SpecificationDetailsModel NumberGT‑12‑2Transducer TypeHigh Temperature UT Probe TransducerMeasurement Range4 – 80 mmOperating Frequency5 MHzContact / Probe Diameter14 mm (nominal)Temperature Range−20 °C to 350 °CApplicationUltrasonic thickness measurementCompatible WithUT thickness gauge devicesUsage EnvironmentIndustrial, heat‑resistant inspectionCore Features and Industrial Benefits1. Wide Measurement Range (4 – 80 mm)The GT‑12‑2 high‑temperature ultrasonic thickness gauge offers a measurement range from 4 mm up to 80 mm. This range supports a broad spectrum of applications, from thin sheet inspections to mid‑range structural components.Whether measuring thin plates or thicker structural sections, the GT‑12‑2 provides:Reliable readings across thin and thick materialsFlexible usage across industries and material typesHigh measurement consistencyThis broad range reduces the need for multiple probes, saving you time and investment.2. Compact Contact Diameter and Ergonomic DesignWith a contact diameter of approximately 14 mm, the GT‑12‑2 probe balances:Enhanced surface contactImproved coupling efficiencyComfortable handling during repetitive measurementsThe compact probe size makes it suitable for:Hard‑to‑reach surfacesLightweight handheld operationRapid point‑to‑point assessmentAn ergonomic design increases operator comfort and improves throughput in routine inspection tasks.3. Durable Construction for Industrial EnvironmentsIndustrial thickness measurement applications demand probes that resist:Thermal stressMechanical vibrationSurface contaminantsRepeated useThe GT‑12‑2 high temperature UT transducer is built with rugged components that resist heat and wear, ensuring dependable performance even under:Shipyard environmentsHeavy fabrication facilitiesPower plant maintenancePetrochemical inspectionsThis robust construction increases service life while reducing downtime and replacement costs.4. Superior Signal Response and Echo ClarityAccurate ultrasonic thickness measurement depends on clean echo patterns and precise signal interpretation. The GT‑12‑2 thickness probe delivers:Strong echo returnsClear signal waveformsMinimal noise interferenceThis superior output enables clear differentiation between material interfaces, increasing confidence in your readings and reducing false readings or misinterpretations.5. Compatible with Multiple Thickness Gauge UnitsThe GT‑12‑2 high temperature ultrasonic thickness gauge probe is designed to work with a wide range of ultrasonic thickness gauge instruments. When integrated into your existing UT system, it expands the functionality of your measurement device, allowing you to:Upgrade to high‑temperature capabilitiesPerform more demanding inspections without investing in new gauge unitsExtend the value of your current equipmentThis compatibility makes the GT‑12‑2 a cost‑effective upgrade for industrial inspection teams.Typical Industrial ApplicationsThe GT‑12‑2 ultrasonic thickness gauge probe is engineered for sectors that demand robust and accurate thickness measurement in high‑temperature environments:Power GenerationUsed for inspecting:Boiler tubesHeat exchangersSuperheater coilsPipe walls in steam linesIn power plants, where surfaces routinely exceed 200 °C, this probe maintains accurate readings without calibration drift.Petrochemical and RefineriesFor piping inspection, vessel integrity assessment, and corrosion monitoring, the high‑temperature UT probe provides:Fatigue crack evaluationWall loss detectionPre‑shutdown inspection coverageInspectors rely on this probe to deliver consistent data in heat‑intensive operations.Marine and OffshoreOffshore platforms and ship hulls often operate in environments where:Heat build‑up occurs near enginesCorrosion monitoring is requiredInspection must be rapid and accurateThis probe supports routine maintenance and condition monitoring with high reliability.Aerospace and AutomotiveHigh precision, heat tolerance, and repeatable readings allow use in:Heat‑treated componentsEngine partsWelded structuresThese industries benefit from ultrasonic thickness measurement that maintains accuracy on complex geometries and hot surfaces.Installation and Setup GuidelinesTo achieve optimal measurement results with your GT‑12‑2 high temperature UT probe transducer:Always use a suitable coupling gel to ensure acoustic contact. Allow the probe to stabilize at temperature before recording readings. Use consistent surface preparation to reduce noise. Validate calibration using a known reference standard.Following these practices improves accuracy and ensures consistent data quality.Maintenance and Care InstructionsThis high temperature ultrasonic thickness gauge probe is built for durability, but proper care extends its service life:Routine CareClean after each use with a soft cloth.Avoid dropping or striking the probe surface.Protect the cable from sharp bends.Thermal HandlingAvoid sudden temperature shock.Allow the probe to cool gradually after extreme heat exposure.Do not exceed the specified temperature limit.StorageStore in a dry, temperature‑controlled environment.Use original packaging or protective case for transport.Common Troubleshooting TipsIssueSolutionUnstable readingsCheck coupling gel, surface preparation, and probe contactWeak echoConfirm calibration and probe alignmentExcessive noiseClean surface, use correct couplant, re‑calibrateOverheating probeAllow materials to cool below max temperature before useThese simple troubleshooting steps help maintain measurement integrity.Frequently Asked QuestionsWhat materials can the GT‑12‑2 ultrasonic thickness probe measure?The GT‑12‑2 is suitable for metals, plastics, composites, and other engineering materials that can be measured using ultrasonic thickness gauge technology. It performs especially well on steels and alloys used in high‑temperature industrial applications.Can this probe measure materials hotter than 350 °C?No. The GT‑12‑2 probe is rated up to 350 °C maximum surface temperature. Surfaces hotter than this may damage the transducer and compromise accuracy.How do I attach the GT‑12‑2 probe to my thickness gauge?Connect the GT‑12‑2 UT transducer to any compatible ultrasonic thickness gauge with the appropriate connector. Follow your thickness gauge manufacturer’s instructions for proper electronics interface and calibration.What is the difference between this high temperature probe and a standard probe?Standard ultrasonic probes typically handle temperatures up to 60 °C – 80 °C. The GT‑12‑2 probe is designed to withstand surfaces up to 350 °C, making it suitable for hot process environments where ordinary probes cannot operate safely.Does the GT‑12‑2 probe require calibration?Like all UT probes, regular calibration is recommended. Use calibration blocks that match the material and thickness range for your application to ensure accurate results.What is the recommended couplant for this probe?High‑temperature couplants are recommended for hot surfaces. These gels maintain acoustic conductivity at elevated temperatures and improve contact between the probe and test surface.Is this probe compatible with every ultrasonic thickness gauge?Compatibility depends on the gauge’s connector type and frequency support. The GT‑12‑2 probe is compatible with most industry‑standard thickness gauges that accept 5 MHz transducers. Check your gauge specifications.Can I use this Probe For corrosion monitoring?Yes, the GT‑12‑2’s accurate thickness measurement capability makes it suitable for corrosion rate tracking and wall‑loss monitoring in high‑temperature systems.You Might Also Need These Products:ASSY SYS5 MF/CAT M BULK HEAD 9063-1191-11-MCSTrimble CAT GCS900 Dozer Scraper Compactor Automatic Harness With AS400 Cable
Olympus

Olympus

  • NL2020HD22 Battery Replacement For Olympus Nortec 500D NL2020 Nortec 500S
    $35.02 $60.93
  • High Temperature Ultrasonic Thickness Gauge Probe GT‑12‑2 Premium UT Transducer For Industrial Precision
    $50.09 $91.16

© 2026 - TMPRESS.ES